I – Parameter definition
S900–II Configuration
Version 2.1
48
01T01506_1
25.11.99
PARAMETER Abbreviation Description Default
value
Function
0523
IN_VER_MOD
Mode locking 127 Input at 1 to lock the robot’s operating modes.
0524
IN_VER_PRG
Programming mode locking 127 Input at 1 to lock the programming mode.
0525
IN_REGLAGE
Adjust mode 127 Input at 1 to select the Adjust mode.
0526
IN_PAS_A_PAS
Step by Step mode 127 Input at 1 to select the Step by Step mode.
0527
IN_AUTO
Automatic mode 127 Input at 1 to select the Automatic mode.
Note : If more than one of the 3 inputs of parameters 525, 526 and 527 are at 1, the robot goes into STOP mode.
0548
IN_STOP
Immediate stop 127 Input at 1 to request the immediate stop of the robot.
0528
IN_X_PLUS
X+ command 127 Input at 1 to request an X+ movement.
0529
IN_X_MOINS
X– command 127 Input at 1 to request an X– movement.
0530
IN_Y_PLUS
Y+ command 127 Input at 1 to request a Y+ movement.
0531
IN_Y_MOINS
Y– command 127 Input at 1 to request a Y– movement.
The default value may vary depending on the type of input / output board. Consult the list of robot parameters, file S.