I – Parameter definition
S900–II Configuration
Version 2.1
26
01T01506_1
25.11.99
TYPE OF OPERATION WITH INJECTION MOULDING MACHINE (IMM) 1
PARAMETER Abbreviation Description Parameter
value
Corresponding function
0170
TYPE_ACCES_1
Type of access to IMM 1 0 Vertical access.
1 Lateral access.
2 Axial vertical access.
3 Mixed access (vertical or lateral). The selection is made by the input of
parameter 453.
Default value :
0
Possible value :
0 –> 3
Interaction with other parameters : 453
0171
TYP_INTFACE_1
Type of interface with IMM 1 0 No interface.
1 For Injection Moulding Machine (IMM) with Euromap 12 as standard
2 IMM cycle validation maintained, for Injection Moulding Machine (IMM)
with SPI as standard.
3 General handling.
Default value :
1
Possible value :
0 –> 3
Interaction with other parameters :