VII – Trouble–shooting
S900–II USER MANUAL
Version 2.1 |–>
44
01T01518_1
25.11.99
VII – 2. 2. Extended monitor mode: forcing a variable
It is possible to force the status of a bit, an input, an output, or change the value of a counter, a Word
or a WWord. This forcing is done in extended monitor mode, accessible in Step by Step or automatic
mode.
Forcing may lead to an unexpected functioning of the robot, and is therefore dangerous.
To move the cursor on the line containing the variable to be forced
Point| TIME | VEL | IMP | ../..
To access the SAP menu
Edit | | STK | | Force
TIMER | WORD | IMM | DIALOG|
Forc
F –>0 | F –>1 | No | |Rstall
for the bits, inputs
or outputs
for the counter,
Word and WWord
To enter the new value
To confirm
To cancel
...
The changeable value flashes on the screen
forced to 0
forced to 1
forcing cancelled for
the selected variable
forcing cancelled for
all the variables
To access the forcing mode
INPUT 016 = 1, 001 0011 1100 0000
OUTPUT 004 = 0, 110 1110 0000 0000
BIT 000 = 0, 000 0000 0000 0000
COUNTER 0000 = 0000_D
WORD 000 = 000000_D
WWORD 000 = 0000 0000_D
TIMER | WORD | IMM | DIALOG|
The robot is in monitor mode.
to access the
program editor