S900–II USER MANUAL
Version 2.1 |–>
V – Manual control of the installation
33
01T01518_1
25.11.99
V – 6. Output control
In an adjust mode screen , the input, output or bit status is marked before the comma, followed
by the status of the next 15 inputs, outputs or bits.
To choose
the number
INPUT 016 = 1, 001 0011 1100 0000
OUTPUT 004 = 0, 110 1110 0000 0000
BIT 000 = 0, 000 0000 0000 0000
COUNTER 0000 = 0000_D
WORD 000 = 000000_D
WWORD 000 = 0000 0000_D
OUT= 0|Out= 1 | Calib. | Offset|
SAP
To power up if necessary
Enter the output
number
To move the
cursor
To access
descriptive
message
Set to 0 Set to 1
To confirm
the selection
Figure 29 :
Output control
Note : The outputs for Arm Free Safety (SBD), Machine Cycle Validation (VCM), Without Robot
Mode, Overtravel Forcing and the pneumatic High Speed outputs cannot be controlled.