III – The axes’ parameters
S900–II CAN and AXES Configuration
Version 2.0 |–>
PARAMETER Abbreviation Description Parameter
value
Corresponding function
616
752
888
1024
1160
ANTICIPM_X
ANTICIPM_Y
ANTICIPM_Z
ANTICIPM_B
ANTICIPM_C
Braking anticipation in –
direction in 1/10 mm.
THIS PARAMETER IS ONLY
APPLICABLE FOR THE
BRAKED ASYNCHRONOUS
AXES.
0 –> 255
Value of the window (compared to the programmed position) in which the motor
brake should be applied. This parameter is used to take into account the brake
reaction time for movements in a negative direction (departure position greater
than arrival position). This parameter adjusts itself automatically
, during the
robot’s movements, according to the distances measured at the end of the path.
Default value :
10
Possible value : 0 –> 255 Interaction with other parameters : 617, 753, 889, 1025, 1161
617
753
889
1025
1161
ATCIP_X
ATCIP_Y
ATCIP_Z
ATCIP_B
ATCIP_C
Maximum braking
anticipation in 1/10 mm.
THIS PARAMETER IS ONLY
APPLICABLE FOR THE
BRAKED ASYNCHRONOUS
AXES.
0 –> 255
Limit value of braking anticipations in a positive and negative direction
(Parameters 615 and 616). The basic task is to monitor the braking anticipations
which are automatically updated. When an anticipated value is greater than the
value in this parameter, the message “
W_00: $ – Braking faulty
warns the user that the brake must be adjusted.
Default value :
250
Possible value : 0 –> 255 Interaction with other parameters : 615–616, 751–752, 887–888, 1023–1024, 1159–1160