Seitenansicht 15
III – The axes’ parameters
S900–II CAN and AXES Configuration
Version 2.0 |–>
Type of control
0 = The axis is stopped by the brakes.
512 = The axis is stopped by the servo–control for the
time defined by parameter 626.
Type of tracking error control
0 = The tracking error is compared to a maximum value
(Parameter 612) and a fault is generated if it is greater
than this value.
1024 = The maximum value of the dynamic distance is
calculated in real time according to the current speed of
the axis and the maximum tolerance (Parameter 612).
The test is then carried out as in the previous case.
Releasing
0 = The axis cannot be freed.
2048 = The axis can be freed.
Type of movement
0 = Linear axis.
4096 = Rotating axis.
The parameter value is the sum of the values selected by each of the Criteria.
Default value :
0
Possible value : 0 –> 65535 Interaction with other parameters : 612, 626, 748, 762, 884, 898, 1020, 1034, 1156, 1170
611
747
883
1019
1155
NUM_AXE_X
NUM_AXE_Y
NUM_AXE_Z
NUM_AXE_B
NUM_AXE_C
Output port associated with
the axis
1 –> 6
Defines the port attributed to the axis’ commands.
. 1 to 3 for the axes board 1 (1 = J6, 2 = J7, 3 = J8)
. 4 to 6 for the axes board 2 (4 = J9, 5 = J10, 6 = J11)
Default value :
1 –> 6
Possible value : 1 –> 6 Interaction with other parameters :