Conair VL Series Bedienerhandbuch Seite 16

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 17
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 15
GSL 9-12-12 IM Page 16
9 TROUBLESHOOTING
Most loader problems are a result of a dirty filter, air leaks or improper adjustments.
These items should be checked before assuming equipment failure.
Problem
Motor will not run
Inadequate or no vacuum
Inadequate or no material flow
Motor runs but proportioning solenoid
not operating
Investigate
A, B, C, H, and L
D, E, F, G, J
D, E, F, and G, I, K
L
CHECK CONDITIONS SOLUTION
A. Power Supply No voltage or voltage incorrect Check incoming
voltage at outlet power supply
B. Stop/Start Switch No voltage through switch Replace switch
C. Vacuum motor No voltage at motor See A,B, & L
D. Filter Filter dirty Replace filter
(Also see G & J)
E. Air Ducts Obstructed Remove obstruction
F. Leaks in system Air leaking into system Replace gaskets &
repair leaks as necessary
G. Blowback air Low pressure Increase pressure
pressure incorrect (not to exceed 125 psi)
H. Limit switch No voltage through switch Replace switch
I. Load Time Chamber not filling sufficiently Increase load time
Chamber over-filling Decrease load time
J. Pulse rate Insufficient to clean filter Increase rate
K. Dump time Insufficient to allow complete Increase time
emptying of chamber
L. Pulse solenoid Correct voltage at solenoid Replace solenoid