Conair Hopper Temperature Controller UGD031 Bedienungsanleitung Seite 76

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 97
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 75
6-12 l Troubleshooting
Replacing the Heating Elements
1 Disconnect and lockout the main power.
2 Gain access to the heating elements by removing screws that
secure the heating element cover to the enclosure.
3 Remove the heating element cover by tilting
the top away from the enclosure slightly, then
lifting the cover up and away from the enclosure.
4 Refer to the “Testing the Installation” section
(page 3-13) and determine which heater(s) is
not functioning.
5 Remove the screws securing the electrical
cover plate
to the heating element enclosure.
Remove the electrical cover plate.
6 Note the connection points then disconnect the heating element leads from
the terminals on the terminal block.
IMPORTANT
: Always refer
to the wiring diagrams
that came with your
heater to locate specific
electrical components.
Illustrations in the User
Guide are intended to be
representative only.
ON
O OFF
Screws to Remove
- Large Heaters
Heater
Wires
Heater
Connection
Junction Box
Seitenansicht 75